Free Shipping for all Order of ₹ 30000

Carestream Kodak Rvg 5200 Digital Radiography System

RVG Sensor For Digital Dental Radiography With 16 lp/mm True Resolution

Check Availability At

Please enter PIN code to check delivery time & Pay on Delivery Availability

Enter the pincode to enable Add to Cart.

Price:

113,000.00

Brand:

Kodak

IMPROVED ERGONOMICS

  • Newly redesigned cable.
  • 20% thinner diameter reduction in cable thickness.
  • Teflon lining reduces the friction of cable wires.
  • Improved flexibility.
  • The weaving of alloy mesh cable shielding optimized for flexibility.

RELIABLE BY DESIGN

  • Reinforced cable connection points are injection molded to increase strength over the previous generation of the RVG sensor.
  • Sensor cable attachment.
  • Connection to USB plug.
  • Higher uptime with lower service costs.

BUILT TO LAST

  • Thanks to rigorous design and testing, all RVG sensors provide maximum durability and flexibility. Completely waterproof, RVG sensors can be safely submerged in disinfectant for improved infection control.
  • The shock-resistant cases and silicon padding offers protection from falls, bites, and other damage, allowing them to stand up to even the toughest day in the operatory. In addition, protective lead layer helps to prevent damage due to repeated high exposure ensuring a long lifespan with an attractive return of investment.

AN AFFORDABLE, HIGH-QUALITY INTRAORAL SENSOR

  • As an entry point into dental digital radiography, the RVG 5200 system is not only easy to use but also remarkably powerful. The image appears immediately upon acquisition, allowing you to save valuable time and focus on what’s important – your patient.
  • No longer have to sacrifice image quality for affordability.

ENHANCED WORKFLOW

  • Workflow is optimized to the extreme: POSITION. EXPOSE. VIEW.
  • No need to activate the sensor prior to image acquisition.
  • RVG sensors are always ready to acquire images.
  • The image is displayed within seconds after X-ray exposure.

TWAIN COMPATIBILITY

  • TWAIN compatibility means the sensor can be integrated with almost any imaging and dental practice management software, including Carestream Dental practice management software.

ENHANCED PATIENT COMFORT

The RVG 5200 sensors ergonomic design makes positioning a breeze, while rounded camera ensures a more comfortable examination for patients. The sensors rear entry cable also assists in positioning and further improve dental care.

RVG Sensor For Digital Dental Radiography With 16 lp/mm True Resolution

TECHNICAL SPECIFICATION OF CARESTREAM KODAK RVG 5200 DIGITAL RADIOGRAPHY SYSTEM:

Technology SuperCMOS Scintillator Optical Fiber
Pixel size 19 μ
True (measured) resolution 16 lp/mm
Active area 22,2 x 29,6 mm
Overall dimensions 27,6 x 37,7 mm
Sensor plate thickness 7, 3 mm
Gray scale 4096 grey levels (12 bit s)
Input voltage (from USB interface) 5V
  • 1 x Kodak RVG 5200 Sensor
  • 1 x Sensor Holders
  • 1 x Sensor Sleeves

How to Installation:

  • Unpacking and Inspection:
  • Carefully unpack the RVG 5200 system and inspect all components for any damage during transportation.
  • Hardware Setup:
  • Connect the RVG sensor to the USB plug on your computer using the provided cable.
  • Ensure a stable and secure connection between the sensor and the computer.
  • Driver Installation:
  • Install the necessary drivers for the RVG 5200 system. These drivers are typically provided on a CD or can be downloaded from the manufacturer’s website.
  • Software Installation:
  • Install the RVG imaging software on your computer. Follow the installation instructions provided with the software.
  • Calibration (if required):
  • Some systems may require calibration. Follow the calibration steps outlined in the user manual or software guide.
  • Integration with Practice Management Software (if applicable):
  • If you are integrating the RVG 5200 with practice management software, follow the specific instructions provided by the software vendor.
  • Testing:  Test the system by capturing a sample image to ensure proper installation and functionality.

How to use:

  • Positioning:
  • Use the ergonomic design of the RVG 5200 sensor for accurate positioning. The rear entry cable may assist in positioning.
  • Exposure:
  • Activate the X-ray machine to expose the image. The RVG 5200 is designed for immediate image acquisition, so there’s typically no need to activate the sensor separately.
  • Image Acquisition:
  • The captured images should appear on the monitor screen within seconds after exposure.
  • Image Processing (if needed):
  • Utilize the user-defined image processing tools provided by the software for customization. This can include adjusting contrast, and brightness, or applying filters.
  • Integration with Imaging Software:
  • If using third-party imaging or practice management software, ensure proper integration through TWAIN compatibility.
  • Patient Comfort:
  • Leverage the ergonomic design to make the examination more comfortable for the patient.
  • Country Of Origin: United States of America
  • Manufacturer: Carestream
  • Manufacturer/Importer warranty for CARESTREAM KODAK RVG 5200 DIGITAL RADIOGRAPHY SYSTEM is 5 Years as applicable for this product.
  • Service and Warranty are handled by the manufacturer/importer directly for this product
  • Supreme Dental will not be liable to replace the Products and the liability to replace any such Product is that of the Manufacturer/Importer
  • Supreme Dental and the Buyer acknowledge that the Products purchased/used are a subject matter of original Manufacturer/Importer’s warranties only
  • Any or all claims in relation to returns and replacement shall be made to the concerned Manufacturer/Importer only and Spreme Dental may assist the customer in registering a request to get the Product replaced or serviced. 
  • The Buyer acknowledges that the Products once sold will not be exchanged or taken back unless the seal of the package or the Product is intact or not altered in any manner or is not tampered as the case may be.

FAQs

Answer: No, the Carestream Kodak RVG 5200 Digital Radiography System cannot be operated directly with an iPad. It requires a wired USB connection to a compatible Windows-based computer for image acquisition and processing.

Answer: You can use multiple RVGs from different brands on the same PC for different chairs. However, you’ll need to install the specific software for each RVG brand. While you can access each system one at a time, ensure your PC meets the requirements: Windows 10, at least 500 GB hard drive, and 8 GB RAM. This setup allows for efficient management of radiographic images across multiple workstations.

Answer: To ensure optimal performance of the Carestream Kodak RVG 5200 Digital Radiography System software, it is advisable to use a laptop with a latest generation processor and a minimum of 8GB of RAM. These specifications help provide a smooth user experience and effective functionality, allowing dental professionals to efficiently manage and analyze radiographic images.

Subtotal:

Total:

Payment Options

Supreme Dental Benefits

Free
Shipping

Hassle Free
Shipping

100% Genuine
Products

Need assistance to buy this product. Connect with the consultation agent.

Share Product Feedback

Reviews

There are no reviews yet.

Be the first to review “Carestream Kodak Rvg 5200 Digital Radiography System”

Your email address will not be published. Required fields are marked *

*Your Review will be held for moderation after submission.